Product 02 / Glazing Curtain Wall

Unitised Glazed Curtain Wall

Seamless floor-to-ceiling glass for high-rise towers. Low-E tempered units are factory-sealed and tested for air leakage, water penetration, structural wind load and cyclic movement before they arrive on site.

Why Unitised Glazing

01

Factory Quality

Units are glazed, sealed and inspected in controlled conditions, then delivered ready to hoist and install.

02

Certified Performance

Four standard tests — air leakage, water penetration, structural wind load and cyclic movement — verify facade integrity.

03

Engineered Detailing

FEA simulation, Eurocode-aligned calculations and BIM-driven shop drawings ensure every component fits.

Specification

Selection & Technical Data

INDECO unitised glazing is specified per project. The table below lists the standard options and the performance levels our engineering team designs to.

ParameterOptions / Performance
System typeUnitised, factory-glazed and sealed
Module sizeUp to 1.5 × 4.0 m per unit
IGU configuration6 mm Low-E + 12 mm argon + 6 mm (6+12A+6); up to 8+16A+12 laminated
Thermal (U-value)≈ 1.4 W/m²·K
Solar control (SHGC)≤ 0.22 · Visible transmittance ≥ 40%
Acoustic (STC)Up to STC 42 with laminated inner lite
Structural windUp to 4.5 kPa (ASTM E330 / ASCE 7-22)
Water tightness750 Pa, no leakage (ASTM E331)
PermeabilityClass A4 (EN 12152)
WatertightnessClass RE 1200 (EN 12154)
Glazing optionsDouble-skin, low-E, solar-control, acoustic laminated

Operating Conditions

Engineered for towers in extreme climates

INDECO unitised glazing is built for the buildings that push façades hardest — supertall towers on coastlines exposed to hurricanes and salt spray, and high-rise commercial blocks in cities with extreme temperature swings. In the Waterfront Commercial Tower (Dubai) specification, the system was engineered for a peak structural wind pressure of 4.5 kPa and held water tightness at 750 Pa with zero leakage — the test regime is set out in our guide to curtain wall performance testing.

Low-E coatings and argon-filled cavities keep solar heat gain low while letting daylight through, cutting both cooling and lighting loads. With laminated inner lites the system reaches STC 42, softening street and façade noise. Marine-grade aluminium frames with anodised or PVDF finishes resist corrosion through 25+ years of coastal service, and every unit is verified for air leakage, water penetration, structural load and cyclic movement before it leaves the factory. Where the elevation needs shading or movement, the glazed fields are paired with a wind-driven kinetic louver facade, and spandrels and soffits are closed with aluminium rainscreen cladding.

Related

Complete the envelope

Glazed fields rarely stand alone. These are the systems and references our engineers most often specify next to a unitised curtain wall.

Get the full curtain wall specification pack

Download Brochure

FAQ

Unitised Glazing — Frequently Asked Questions

What is a unitised curtain wall?

A unitised curtain wall is a glazed façade built from large modules assembled and sealed in the factory, then craned into place on site. Because the weather-tight unit is completed off-site, quality control is higher and on-site installation is faster than stick-built systems.

How much wind and water can unitised glazing withstand?

INDECO unitised glazing is tested for structural wind load, water penetration, air leakage and cyclic movement. In the Waterfront Commercial Tower (Dubai) specification, the system was engineered for peak structural wind pressure up to 4.5 kPa (ASTM E330 / ASCE 7-22) and water tightness at 750 Pa with no leakage (ASTM E331).

What is the insulated glass (IGU) configuration?

A typical INDECO unit pairs a Low-E tempered outer pane, a warm-edge argon-filled cavity and an inner lite — for example 6 mm Low-E + 12 mm argon + 6 mm (6+12A+6). The Dubai specification used 8 mm Low-E + 16 mm argon + 12 mm laminated for higher security and acoustics.

See all FAQs across INDECO systems →